20min Biological Indicator for Steam SKU: BT224

20min Biological Indicator for Steam SKU: BT224
20min Biological Indicator for Steam SKU: BT224
20min Biological Indicator for Steam SKU: BT224

20min Biological Indicator for Steam SKU: BT224 Specification

  • Size
  • Standard
  • Color
  • Blue
  • Storage Instructions
  • Cool & dry place
  • Product Type
  • 20min Biological Indicator for Steam SKU: BT224
  • Use
  • Medical
  • Shape
  • Rectangle
  • Warranty
  • 1 Year
 
 

About 20min Biological Indicator for Steam SKU: BT224

Bionova Ultra Rapid Self-contained Biological Indicator Specification

Brand
Bionova

Process
Steam

Packaging
50 indicators per pack

Microorganism
Geobacillus stearothermophilus ATCC 7953

Population
One million spores per carrier

Readout Time
20 minutes

Regulations
IRAM 37102 Part 1, IRAM 37102 Part 3, ISO 11138, ISO 11138 Part 1, ISO 11138 Part 3

Target Market
Dental, Healthcare, Pharmaceutical

Description
Ultra Rapid Self-contained Biological Indicator for Steam sterilization processes. Final readout in 20 minutes. FDA cleared. Optional visual pH color change can be checked after 48 hours. A 7-day readout is optional for validation purposes. D-Value is not lower than 1.5 minutes at 121 degrees Celsius. Additional D-Values are available at 132 degrees and 135 degrees Celsius. Z-Value is provided.

Instructions for Use

  1. Label the SCBI with sterilizer number, load number, and processing date.

  2. Place SCBI with the materials to be sterilized in areas least accessible to steam.

  3. Perform sterilization cycle.

  4. After sterilization, wait five minutes and remove SCBI using safety glasses and gloves.

  5. Check Process Indicator for a brown color to confirm exposure to steam.

  6. Seal the tube, crush the ampoule, shake to soak the spore carrier, and place in the incubator.

  7. Incubate processed and positive control indicators in the Terragene Bionova Auto-Reader incubator for 20 minutes at 60 degrees Celsius. Fluorescence detection indicates sterilization failure. Positive control must give positive fluorescence.

Notes

  • Positive control should be used at least once per day.

  • Holding time between sterilization and incubation should not exceed seven days.

  • Fluorescence detection wavelength is 340 to 380 nanometers excitation and 455 to 465 nanometers emission.



Fast and Reliable Sterilization Assurance

The 20min Biological Indicator for Steam offers medical professionals a quick and trustworthy way to confirm the efficacy of their steam sterilization cycles. With results available in just 20 minutes, users can reduce downtime and ensure prompt equipment turnaround, enhancing operational efficiency in medical environments.


User-Friendly Design with Optimal Storage

Featuring a standard size and rectangular shape, the blue-colored indicator is easy to handle and integrate into standard sterilization procedures. To maintain product integrity, it should be stored in a cool, dry place as per the provided instructions, ensuring accurate performance during each use.

FAQ's of 20min Biological Indicator for Steam SKU: BT224:


Q: How should the 20min Biological Indicator for Steam (BT224) be used in a medical setting?

A: Place the rectangle-shaped indicator inside the load to be steam sterilized. After the sterilization cycle, incubate the indicator as directed. Within 20 minutes, a color change or readout will signal if sterilization was successful.

Q: What are the key benefits of using this biological indicator?

A: It provides rapid and reliable confirmation of sterilization within 20 minutes, helping medical staff ensure equipment safety and regulatory compliance while minimizing workflow interruptions.

Q: When should I use the BT224 Biological Indicator?

A: Use this indicator during routine monitoring of steam sterilization cycles in medical facilities, particularly whenever fast validation or documentation of sterilization performance is required.

Q: Where can this product be purchased or supplied in India?

A: The BT224 Biological Indicator is available through authorized distributors, suppliers, and traders across India, catering specifically to the medical sector.

Q: What is the proper way to store the biological indicator?

A: Store the indicator in a cool and dry place. Proper storage ensures the product's reliability and extends its shelf life, maintaining accurate performance every time.

Q: What does the 1-year warranty cover?

A: The 1-year warranty covers manufacturing defects and ensures product reliability during its intended use, providing peace of mind to users across medical environments.

Q: Can this indicator be used with all steam sterilizers?

A: Yes, the BT224 is designed for standard steam sterilization protocols and is compatible with most conventional steam sterilizers used in medical facilities.

  • Minimum Order Quantity
  • 1 Piece
Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Biological Indicators Category

20min Biological Indicator for Steam SKU: BT224

20min Biological Indicator for Steam SKU: BT224

Price 600 INR / Piece

Minimum Order Quantity : 1 Box

Color : Blue

Size : Standard

Use : Medical

Product Type : 20min Biological Indicator for Steam SKU: BT224

30min Biological Indicator for Hydrogen Peroxide SKU: BT96

30min Biological Indicator for Hydrogen Peroxide SKU: BT96

Price 600 INR / Piece

Minimum Order Quantity : 1 Pack

Color : Transparent

Size : Standard

Use : Medical

Product Type : 30min Biological Indicator for Hydrogen Peroxide SKU: BT96

4h Rapid Self-contained Biological Indicator for EtO SKU: BT110

4h Rapid Self-contained Biological Indicator for EtO SKU: BT110

Price 400 INR / Piece

Minimum Order Quantity : 1 Pack

Color : Green

Size : Standard

Use : Medical

Product Type : 4h Rapid Selfcontained Biological Indicator for EtO SKU: BT110



arrow